ASA C37.35-1962 : ASA American Standard Guide for the Operation and Maintenance of High Voltage Disconnecting Switches /

High voltage disconnecting switches are assigned certain ratings by the manufacturer and standard tests are conducted to assure the user that the switch, when new, will perform within the ratings shown on the nameplate. It should be recognized that the switch in service will perform within these rat...

Celý popis

Uloženo v:
Podrobná bibliografie
Korporativní autor: Institute of Electrical and Electronics Engineers (Autor)
Médium: Elektronický zdroj E-kniha
Jazyk:angličtina
Vydáno: [Place of publication not identified] : IEEE, 1961.
Témata:
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!

MARC

LEADER 00000nam a2200000 i 4500
001 9918388362402561
005 20231206214323.0
006 m o d
007 cr |||||||||||
008 231206s1961 xx o 000 0 eng d
020 |a 1-5044-0487-4 
024 7 |a 10.1109/IEEESTD.1961.8684420  |2 doi 
035 |a (CKB)3710000000618997 
035 |a (NjHacI)993710000000618997 
035 |a (EXLCZ)993710000000618997 
040 |a NjHacI  |b eng  |e rda  |c NjHacl 
050 4 |a TK153  |b .I57 1961 
082 0 4 |a 621.3  |2 23 
110 2 |a Institute of Electrical and Electronics Engineers,  |e author. 
245 1 0 |a ASA C37.35-1962 :  |b ASA American Standard Guide for the Operation and Maintenance of High Voltage Disconnecting Switches /  |c IEEE. 
246 |a ASA C37.35-1962 
264 1 |a [Place of publication not identified] :  |b IEEE,  |c 1961. 
300 |a 1 online resource 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
588 |a Description based on publisher supplied metadata and other sources. 
520 |a High voltage disconnecting switches are assigned certain ratings by the manufacturer and standard tests are conducted to assure the user that the switch, when new, will perform within the ratings shown on the nameplate. It should be recognized that the switch in service will perform within these ratings only if properly operated and maintained. It cannot be stressed too strongly that prescribed safety rules should be adhered to at all times when operating or maintaining high voltage disconnecting switches near energized equipment or conductors. 
650 0 |a High voltages. 
650 0 |a Electrical engineering. 
906 |a DOCUMENT 
924 |u http://primo-49man.hosted.exlibrisgroup.com/openurl/MAN/MAN_UB_service_page?u.ignore_date_coverage=true&rft.mms_id=9918388362402561  |b BSO  |p IEEE Electronic Library (IEL)  |8 53199416110002561